Описание
MD SERIES – double stage- single impeller
Compact Execution MOR
TS SERIES – single stage -double impeller
Compact Execution MOR
TD SERIES – double stage – double impeller
Compact Execution MOR
Atex CAT 2G and 3GD Certifications
Use: to move air and technical gases, including methane/biogas, in compression and vacuum systems.
Available solutions:
MS SERIES – single stage – single impeller
Compact Execution MOR
Capacity up to 1022 m³/hr (50Hz) / 1234 m³/hr (60Hz)
Max. differential pressure: 500 mbar
Ambient temperature from -15 to +40°C
Two-pole electric motors, insulation class F – Tropicalised and IP55 protection
Singlephase or threephase (Bimetallic thermal protector PTO S01 150°C)
MD SERIES – double stage- single impeller
Compact Execution MOR
TS SERIES – single stage -double impeller
Compact Execution MOR
TD SERIES – double stage – double impeller
Compact Execution MOR
Atex CAT 2G and 3GD Certifications
Low pressure axial fans are suitable for the transportation of big volume of air and are used for the aspiration of air and smokes, both in industry and civil environments.
The low profile of the MIXVENT-TD fans makes them the most effective solution for installations where the space of installation is limited such as false ceilings.
Easy to mount.
Range of low profile in-line mixed flow duct fans manufactured in tough reinforced plastic (till 800 model) or with metal casing steel finished in a tough epoxy-polyester paint coating (for models 1000 to 6000).
The unique design of the support bracket allows the motor and impeller assembly to be fitted or removed without dismantling the adjacent ducting.
BP V=180 ÷ 20.100 m3/h Pt = 15 ÷ 220 kg/m2
Use: for the removal of clean or slightly dusty air.
They have high efficiency and reduced noise level, the fans of this series are largely used, inventilation, conditioning, drying, cooling, mechnical draft, and toxic gas elimination plants. The temperature of the fluid transported must not exceed 80°C without cooling fan and 150° C with cooling fan. For higher temperatures it is necessary to modify the construction of the fan.
VSA V =250 ÷ 18.000 m3/h Pt = 27 ÷ 330 kg/m2
VSA series is used in chemistries and pharma industries, and in plants that use corrosive substance; highly resistant to chemical agents, especially organic solvents. Manufactured entirely from corrosive resistant material ensuring any surface that may come into contact with the corrosive fume has no metallic components.
Produced completely by injection moulding (up to VSA30); by welding up to VSA70.
Polypropylene housing resistant to UV rays and adjustable to 8 positions.