Descriere
MD SERIES – double stage- single impeller
Compact Execution MOR
TS SERIES – single stage -double impeller
Compact Execution MOR
TD SERIES – double stage – double impeller
Compact Execution MOR
Atex CAT 2G and 3GD Certifications
Use: to move air and technical gases, including methane/biogas, in compression and vacuum systems.
Available solutions:
MS SERIES – single stage – single impeller
Compact Execution MOR
Capacity up to 1022 m³/hr (50Hz) / 1234 m³/hr (60Hz)
Max. differential pressure: 500 mbar
Ambient temperature from -15 to +40°C
Two-pole electric motors, insulation class F – Tropicalised and IP55 protection
Singlephase or threephase (Bimetallic thermal protector PTO S01 150°C)
MD SERIES – double stage- single impeller
Compact Execution MOR
TS SERIES – single stage -double impeller
Compact Execution MOR
TD SERIES – double stage – double impeller
Compact Execution MOR
Atex CAT 2G and 3GD Certifications
Low pressure axial fans are suitable for the transportation of big volume of air and are used for the aspiration of air and smokes, both in industry and civil environments.
EU V =380 ÷ 70.000 m3/h Pt = 45 ÷ 550 kg/m2
Use: for sucking in very dusty air containing various types of materials in suspension.
The main feature of these types of fans is the association of high output (deriving from the use of a rotor with reversed blades, special profile), with the suction of dusty fluids or those containing granular materials.
Besides these fans are characterized by a very flat curve of the absorbed power, in order not to overload the motor neither when working with open inlets.
They are assembled in joineries for transporting saw dust and wooden shavigs, excluding filamentaus material, in mechanical industries for sucking in metal chips, in pneumatic transport of the cement factories, ceramic factories, mills, fodder factories, tanneries, founderies, in textil and chemical Industries and in general in all those apllications where it is necessary to transport harmful air with low and medium pressure.
BP V=180 ÷ 20.100 m3/h Pt = 15 ÷ 220 kg/m2
Use: for the removal of clean or slightly dusty air.
They have high efficiency and reduced noise level, the fans of this series are largely used, inventilation, conditioning, drying, cooling, mechnical draft, and toxic gas elimination plants. The temperature of the fluid transported must not exceed 80°C without cooling fan and 150° C with cooling fan. For higher temperatures it is necessary to modify the construction of the fan.
Designed to respect the service conditions in the dangerous environments as per ATEX normative, offering safety and reliability.
Certificate for 1G 2G 21D 22D Zones:
CEII2G Ex db IIC T5-T3 Gb
CEII3G Ex ec IIC T4 Gc
CEII2D Ex tb IIIC T125° Db
CEII3D Ex tc IIIC T125 °C Dc